Converter Assembly Component Replacement Procedures
Chapter 4
Heatsink Fan Assembly
See
Chapter 1 - Component Diagrams and Torque Specifications
to locate
components in these instructions.
Remove Components
1. Read and follow the
and
2. Remove safety shields and enclosure covers as needed.
3. Carefully cut the plastic wire ties (do not cut the wires) and label each
connector for the Fan Capacitor or TB12.
4. Label and remove the wires from TB12 to the Transformer (120, N, PE).
5. Remove the 12 mounting bolts for the heatsink fan mounting plate.
6. Carefully remove the mounting plate and fan. You may need to pry the
mounting plate away from the gasket. Remove the gasket if damaged.
7. Remove the four heatsink fan mounting bolts and remove the heatsink fan
from the mounting plate.