Rockwell Automation 20P PowerFlex DC Drive - Frame C Pulse Transformer Circuit Board User Manual

Page 12

Advertising
background image

12

Rockwell Automation Publication 20P-IN010C-EN-P - February 2012

PowerFlex DC Drive Frame C Pulse Transformer Circuit Board

2. Connect the leads of the multimeter to pins 13 and 14 of connector XR on

the Pulse Transformer board (polarity is not important) and, using the TA
potentiometer in the center of the Pulse Transformer circuit board, set the
total resistance (RTA) to the appropriate value as indicated in

Table 3 -

or

Table 4 -

in the

Total Resistance Values

section on

page 13

.

1 . . . . . . . . . . . . . .13 . . . . . . . . . . . . . . . . . . . . 33

2 . . . . . . . . . . . . . 14 . . . . . . . . . . . . . . . . . . . 34

XR

The XR connector is located on the
upper right corner of the Pulse
Transformer circuit board.

The TA potentiometer is located on the lower right corner of the Pulse
Transformer circuit board next to the control power terminal block.

Advertising