8

Rockwell Automation Publication 20P-IN010C-EN-P - February 2012

PowerFlex DC Drive Frame C Pulse Transformer Circuit Board

5. Remove the appropriate gate leads (see

Figure 1 - on page 6

for location):

For non-regenerative drives, remove each pair of (orange and yellow)

gate lead cables from connectors KG1…KG6 and push each lead
through the appropriate opening in the board.

For regenerative drive, remove each pair of (orange and yellow) gate

lead cables from connectors KG01…KG06 and KG1…KG6 and push
each lead through the appropriate opening in the board.

6. Remove the cable from connector XTA on the Pulse Transformer board

(see

Figure 1 - on page 6

for location).

IMPORTANT

Carefully remove the gate leads by grasping the connector. DO NOT pull the
gate leads off by pulling on the wires.

=

Remove cable

Remove gate
leads

Regenerative Drive

Non-Regenerative Drive

Remove cable

Remove gate
leads