5. Programming
ATTENTION
Wait at least 6s after programming the Bulletin 161 before issuing a start or rest command, switching
off the power supply or pressing any other key on the control panel.
5.1 Description of the control panel
The Start-key will start operation in the direction
of rotation defined under parameter
F04
; not
active when control is via the terminal block.
4-position LED display to display
parameters and operating data.
Stop/Reset-key. The Stop command (see
b87
)
or reset function for clearing fault indications can
be used via the control panel or the terminal
block.
The RUN LED will be lit when the drive
is in operation, i.e. if a start command
has been given.
The SEL key is used to select and exit input
mode.
The PRG LED will be lit when the drive
is programmed.
The ENTER key is used to save the entered
data.
The Hz and A LED will inform you
whether the output frequency or output
current is displayed.
The arrow keys are used to select parameters
and enter or modify data.
The commanded frequency can be set
via the speed potentiometer.
Programming guide
d01
d09
F01
F04
A ..
C ..
B ..
A01
A98
C01
C91
Entry of
parameters
b01
b89
Saving entered
parameters