Troubleshooting, Error and warning codes – Rockwell Automation 837E Solid-State Temperature Sensors User Manual
Page 25

837E Solid-State Temperature Sensors User Manual
Troubleshooting
Pub #75054-004-08, March 2013
23
Troubleshooting
Error and warning codes
If an error occurs in the electronics, the color of the status LED changes from green to red
and the display shows an error or warning code, as outlined below:
• E-code for errors
In the event of an error message, the measured value is unreliable.
• W-code for warnings
In the event of a warning, the measured value is still reliable.
Error Codes
Code
Explanation
E011
Device configuration faulty
E012
Error in measurement
E015
Device error (internal)
E019
Power supply has undervoltage/overvoltage
E020
Device error (internal)
E021
Device error (internal)
E022
USB supply voltage
E025
Switching contact 1 is not open, although it should be open
E026
Switching contact 2 is not open, although it should be open
E040
Device error (internal)
E042
Output current cannot be generated.
Possible cause: analog output not connected or open circuit
E044
Excessive output current drift (±0.5 mA)