Repair, Change status – Rockwell Automation 837E Solid-State Temperature Sensors User Manual
Page 26
![background image](/manuals/577490/26/background.png)
837E Solid-State Temperature Sensors User Manual
Troubleshooting
24
Pub #75054-004-08, March 2013
Warning Codes
Repair
Bulletin 837E temperature switches are not repairable.
Change Status
The release number on the nameplate and in the Operating Instructions indicates the
change status of the device: XX.YY.ZZ (example 01.02.01).
Code
Explanation
W107
Simulation active
W202
Temperature outside the sensor range
W209
Device start-up
W210
Configuration modified
W212
Sensor signal outside the permitted range
W250
Number of switch cycles exceeded
W270
Short-circuit at output 1
W280
Short-circuit at output 2
XX
Change in the main version.
Compatibility no longer provided. Device and Operating Instructions change.
YY
Change in functionality and operation.
Compatibility provided. Operating Instructions change.
ZZ
Troubleshooting and internal modifications.
Operating Instructions do not change.