10

Table 2: Status indicators of the sender

Figure 6: Status indicators of the receiver

Display

Meaning

Yellow

Supply voltage OK

System error. Disconnect the supply voltage to the SafeShield
safety light curtain for at least 3 seconds. If the problem
persists, replace the unit.

The device is in the test mode.

Noncoded operation (only after switching on)

Operation with code 1 (only after switching on)

Operation with code 2 (only after switching on)

Other

displays

All other displays are error messages. Please refer to “Fault
Diagnosis” on page 32

Display

Meaning

Orange

Cleaning or realignment required

Yellow

Reset required

Red

System providing signals for shutting down the machine
(switching output off)

Green

System enabled (switching output on)

Bypass active (only in conjunction with the SafeShield
function module)

System error. Disconnect the supply voltage to the SafeShield
safety light curtain for at least 3 seconds. If the problem
persists, replace the unit.

Poor alignment to sender.
Please refer to “Aligning Sender and Receiver” on page 30.

Operation with large protective field width (only after
switching on)

Operation with reduced resolution and/or blanking

Noncoded operation (only after switching on)

Operation with code 1 (only after switching on)

-

--

Yellow

7-segment display

Orange

Green

Red

-

Table 3: Status indicators of the receiver

Configurable Functions

This section describes the functions of the safety light curtain which
are selectable via software. Some of the functions can be combined.
An overview of the possible combinations and possible limitation is
given in the section “Functions that Cannot Be Combined” on page
21.

When starting to configure the device, you may save an application
name with a maximum of 22 characters. Use this function as a
“memory jog,” e.g. to describe the application of the current device
configuration. Device symbol SafeShield safety light curtain Host
(receiver) or SafeShield safety light curtain Host (sender), context
menu Configuration draft, Edit, file card General, option
Application name.

Operation with code 2 (only after switching on)

Emergency stop active

Other

displays

All other displays are error messages. Please refer to “Fault
Diagnosis” on page 32.

--

ATTENTION:

Test the protective device

after any changes!

Changes to the configuration of the devices
can degrade the protective function. After
every change to the configuration you must
therefore check the effectiveness of the
protective device (see “Test Notes” on page
31).

The person who makes the change is also
responsible for the correct protective
function of the device. When making
configuration changes, always use the
password hierarchy provided by Allen-
Bradley Guardmaster to ensure that only
authorized persons make changes to the
configuration.