Rockwell Automation 442L SafeShield Safety Light Curtain Hardware User Manual
Page 20
 
SafeShield Safety Light Curtain Hardware User Manual
20
With the aid of the SCD diagnostics function, you can 
check whether defined areas have been changed using 
teach-in. Menu Project, Connect. Then device symbol 
for the related system, context menu Diagnostics, Show.
Reduced Resolution
Under reduced resolution, the light curtain ignores the interruption 
of 1, 2 or 3 adjacent beams. Objects which are not larger than 
specified in Table 12 may be moved through the light curtain 
without the light curtain changing to red (Figure 17, 
➊ and ➋).
Figure 17: Schematic layout of the operation with reduced resolution 
(example: reduction by one beam)
Table 12: Effective resolution and maximum size of moving objects under 
reduced resolution
Notes
• The reduced resolution function can only be used with
the SafeShield safety light curtain with a physical 
resolution of 14mm.
• The first beam of the light curtain (close to the 7-
segment display) must not be interrupted. Otherwise, 
the safety light curtain will change to red.
Physical
resolution
Reduction
Effective
resolution
Maximum size
of movable
objects
14mm
1 beam
22mm
10mm
2 beams
30mm
18mm
3 beams
37mm
25mm
ATTENTION: Test the protective 
device after teach-in!
➢
Test the entire protective device for 
effectiveness (see “Test Notes” on page 
31).
➢
Check whether the safety light curtain 
behaves as expected when you introduce 
the object into the protective field, 
remove it again, or operate the system 
without the object.
➢
If required, recalculate the safety distance 
and readjust it on the machine.
!
• The system response time does not change under
reduced resolution.
• You cannot combine the function Reduced resolution with
the function Floating blanking with partial object monitoring 
(see page 17).
• With reduced resolution, the 7-segment display
indicates
as soon as sender and receiver are aligned.
Figure 18: Marking the effective resolution on the device label
Device symbol SafeShield safety light curtain Host 
(receiver), context menu Configuration draft, Edit, file 
card Host or Guest for the related system, option 
Reduced resolution. Here you can adjust the effective resolution 
in millimetres directly.
Sender Test
The SafeShield safety light curtain sender has a test input on pin 3 
for checking the sender and the related receiver. During the test, 
the sender no longer emits light beams. Thus, it simulates — for 
the receiver — an interruption of the protective field.
Resolution modified 
to: (please mark)
Physical resolution
14mm
30mm
Reduction
Effective Resolution/min. object size
1 beam
22mm
√
50mm
2 beams
30mm
70mm
3 beams
37mm
90mm
n beams
mm
mm
ATTENTION:
Check the safety
distance!
The safety distance required under reduced 
resolution depends on the effective 
resolution.
➢
If required, recalculate the safety distance 
and readjust it on the machine.
Example: – physical resolution 14mm
– resolution reduced by 1 beam
– effective resolution 22mm
Calculate the safety distance
with a resolution of 22mm (see 
page 21).
➢
Mark the effective resolution on the 
information label “Operation with 
reduced resolution or blanking ... on the 
related sender and receiver.
ATTENTION: During operation with 
“Reduced resolution” or “Blanking” the 
safety distance that corresponds to the 
modified resolution is to be observed.
!