Rockwell Automation 442L SafeShield Safety Light Curtain Hardware User Manual
Page 24
 
SafeShield Safety Light Curtain Hardware User Manual
24
Figure 21: Graph, minimum distance from reflective surfaces
Steps for Mounting the Device
and receiver are aligned correctly. The optical lens systems 
of sender and receiver must be located in exact opposition 
to each other; the display elements must be mounted at 
the same height. The system plugs of both devices must 
point in the same direction.
➢
Take suitable measures to attenuate vibration if the 
shock requirements are above the values given in the 
“Data Sheet” section on page 35.
➢
Observe the safety distance of the system during 
mounting. On this topic read the “Determining the 
Safety Distance” on page 21.
➢
Connect a maximum of three systems into a cascaded 
system.
➢
Always connect sender-sender and receiver-receiver 
within a system configuration.
➢
Mount the safety light curtain such that the hazardous 
point cannot be reached from below, above or behind 
the safety light curtain and that the light curtain cannot 
be repositioned.
ATTENTION: Special features to note 
during mounting:
•
Always mount the sender and receiver 
parallel to one another.
•
During mounting, make sure that sender
Figure 22: The correct installation (above) must eliminate the errors 
(below) standing behind, reaching below and reaching above
➢
Once the system is mounted, one or several of the 
enclosed self-adhesive safety information labels must be 
affixed.
♦
Use only labels in the language which the operators of
the machine understand.
♦
Affix the information labels such that they are easily
visible by the operators during operation. After 
attaching additional objects and equipment, the 
information labels must not be concealed from view.
♦
Affix the information label “Important Notices” to the
system in close proximity to sender and receiver.
♦
Operation with floating blanking: Affix the information
label for floating blanking to each sender or receiver so 
configured. Mark the effective resolution on the 
information label.
♦
For operation with reduced resolution: Affix the
information label for reduced resolution to each 
sender or receiver so configured. Mark the effective 
resolution on the information label.