Configuration, Care and maintenance, Fault diagnosis – Rockwell Automation 442L SafeShield Safety Light Curtain Hardware User Manual

Page 32

Advertising
background image

SafeShield Safety Light Curtain Hardware User Manual

32

Note

In all three tests, the receiver of the SafeShield safety light
curtain must show the red LED only.

Figure 36: Daily checks of the protective device

Configuration

Delivery Status

As delivered the SafeShield safety light curtain is configured ready
for protective operation.

Table 19: Delivery status of the SafeShield safety light curtain

Preparing the Configuration

How to prepare the configuration:

➢ Make sure that the safety light curtain has been correctly

mounted and that the electrical connections are correct and in
place.

➢ Plan all required settings (operating mode, beam coding,

resolution, cascading etc.)

To configure the safety light curtain, you need:
• SCD software on CD-ROM
• User manual for SCD on CD-ROM

Function that Can Be Configured

SafeShield

Restart interlock

External

External device monitoring (EDM)

Deactivated

Beam coding

Non-coded

Blanking

None

Scanning range
0-2.5 m or 0-6 m

!

2-6 m or 5-19 m

• PC/Notebook with Windows 9x/NT 4/2000 Professional/XP and

a serial interface (RS-232). PC/Notebook not included

• Connecting cable for connecting PC and SafeShield safety light

curtain 442L-ACRS232

➢ To configure the device, please read the user manual for the

SCD software and use the online help function of the
programme.

Care and Maintenance

The SafeShield safety light curtain is maintenance-free. The front
screen of the SafeShield safety light curtain and any additional front
screen(s) (see “Additional Front Screen (Weld Spark Guard)” on
page 45) should be cleaned at regular intervals and when dirty.

➢ Do not use aggressive cleaning agents.
➢ Do not use abrasive cleaning agents.

Note

Static charges cause dust particles to be attracted to the
front screen. You can prevent this effect by using the
antistatic plastic cleaner.

How to clean the front screen and/or the additional front
screen (optional extra):

➢ Use a clean and soft brush to remove dust from the front

screen.

➢ Then wipe the front screen with a clean and damp cloth.

Note

➢ After cleaning, check the position of sender and receiver to

make sure that the protective device cannot be bypassed
(reaching above, below or behind).

➢ Verify the effectiveness of the protective device as described in

“Test Notes” on page 31.

Fault Diagnosis

This section describes how to identify and remedy errors and
malfunctions during the operation of the safety light curtain.

Recommendation

You can speed up the fault diagnostics of some frequent faults by
querying a signal on the signal output on the safety light curtain on
the occurrence of the fault. Details can be found in “Signal Output
(ADO)” on page 12.

What To Do in Case of Faults

ATTENTION: Cease operation if the
cause of the malfunction has not been
clearly identified!

Stop the machine if you cannot clearly
identify or allocate the error and if you
cannot safely remedy the malfunction.

Advertising