Rockwell Automation 1395 DC Drive, 800-1250 Hp, FRN 5.XX-9.30 User Manual

Page 173

Advertising
background image

Chapter 6
Start–Up

6-8

Table 6.F
Basic Parameters

Parm

606
607
608
609
610
611
612
615
616
617
621
629
651
652
663
664
733
739
740

Parameter Name

Base Motor Speed
Rev Speed Limit
Fwd Speed Limit
Encoder PPR
Rated Motor Volt
Motor Arm FLA
Rated FLD Mtr Cur
Rated Arm Brdg I
Rated Field Brdg I
Rated AC Line
Feedback Device Type
Motor Overload Select
Accel Time
Decel Time
Fwd Brdg Current Limit
Rev Bridge Current Limit
Arm Bridge Type
K Arm Volts
K AC Volts

Value

Motor Nameplate
Application
Application
Encoder Nameplate
Motor Nameplate
Motor Nameplate
Motor Nameplate
Table 6.G
Table 6.H
AC Input Voltage to Drive
Motor Feedback
Motor Enclosure
Application
Application
Application
Application
Drive Nameplate
Table 6.I
Table 6.I

Classification

Table 6.G
Rated Arm Brdg I (Parm 615)

HP @230VAC, 250VDC

400 HP
500 HP
600 HP

HP@ 460VAC, 500VDC

Rated Armature Bridge Current

HP@ 660VAC, 700VDC

1350 Amps, DC
2250 Amps, DC
2250 Amps, DC

Rated Armature Bridge Current

700 HP
800 HP
900 HP

1000 HP
1250 HP

900 HP

1000 HP
1250 HP
1500 HP
1750 HP
2000 HP

Rated Armature Bridge Current

1350 Amps, DC
1350 Amps, DC
2250 Amps, DC
2250 Amps, DC
2250 Amps, DC
2250 Amps, DC

1350 Amps, DC
1350 Amps, DC
2250 Amps, DC
2250 Amps, DC
2250 Amps, DC

Table 6.H
Rated Fld Brdg I Settings (Parameter 616)

J1 Jumper

1
2
3
4

400 – 600 HP, 240VDC

42.4 A
18.5 A

8.7 A
2.4 A

700 – 1250 HP, 500VDC

1000 – 2000 HP, 700VDC

42.4 A
18.5 A

8.7 A
2.4 A

42.4 A
18.5 A

8.7 A
2.4 A

Advertising