Chapter 2
Hardware Description

2-10

Armature Pulse Transformer (A24, A24A, A25, A25A) –
The primary functions of the Armature Pulse Transformer Board
(Figure 2.8) include:

Isolate power bridge circuitry from control circuitry.

There are 4 Armature Pulse Transformer Boards. Each board is associated
with each of 4 commutation groups. There are four boards for the Regen
and two for the Non-Regen. The board is physically mounted on the
armature power bridge, with screw terminals used to mount the board also
used as the connections to the incoming AC line and DC bus. SCR
connections are made at the spade terminals with the red and gray color
designations on the right side of the board.

Figure 2.8
Armature Pulse Transformer Board Hardware Location

J1

T1

T2

T3

C1

C2

C3

BR1

BR2

BR3

R3

R6

R9

R1

R4

R7

Red

Gray

Red

Gray

Red

Gray

A1, 4

A3, 6

A2, 5

Advertising