Description, Specification quick reference, Catalog numbers – Rockwell Automation 1606-XLSRED40 Power Supply Reference Manual User Manual

Page 2: Certification marks, Mosfet redundancy module

Advertising
background image

All parameters are specified at 24V, 40A output current, 25°C ambient and after a 5 minutes run-in time, unless noted otherwise.

2

Rockwell Automation Publication 1606-RM010A-EN-P — February 2014

Bulletin 1606 Switched Mode Power Supplies

For N+1 and 1+1 Redundant Systems
Dual Input with Single Output
Suitable for all Power Supplies
Only 72mV Voltage Drop at 20A Output Current
Only 2.15W Loss at 20A and 6.3W at 40A Output Current
160% (65A) Peak Load Capability
Reverse Input Polarity Protection
Full Power Between -40°C and +70°C
Width only 36mm
Rugged Metal Housing
Easy Wiring:
Distribution Terminal for Negative Pole Included
3 Year Warranty

Description

The 1606-XLSRED40 is a redundancy module which can
be used to build 1+1 and N+1 redundant systems. It is
equipped with two input channels, which can be
connected to power supplies with up to 20A output
current and one output, which can carry nominal
currents up to 40A. The module is suitable for power
supplies with constant current overload behavior as well
as any kind of “Hiccup” overload behavior.

The novelty of this redundancy module is the utilization
of mosfets instead of diodes for the decoupling of the
two input channels. This reduces the heat generation
and the voltage drop between input and output. The
redundancy module does not require an additional
auxiliary voltage and is self-sufficient even in case of a
short circuit across the output.

Due to the low power losses, the unit is very slender and
only requires 36mm width on the DIN

rail. Large

connection terminals allow for a safe and fast
installation with a large international approval package.
This unit is suitable for nearly every application.

Specification Quick Reference

Input voltage

DC 12-28V

±30%

Input voltage
range

8.4-36.4Vdc

Input current

2x 0-20A

continuous

2x 20-32.5A

for 5 seconds

Output current

0-40A

continuous

40-65A

for 5 seconds

65A

at cont. overload
or short circuit

Input to output
voltage drop

typ. 72mV
typ. 112mV
typ. 140mV

input: 2x10A
input: 1x20A
input: 2x20A

Power losses

typ. 700mW

at no load

typ.

2.15W

input:

2x10A

typ.

2.65W

input:

1x20A

typ. 6.3W

input: 2x20A

Temperature range -40°C to +70°C

operational,
no de-rating req.

Dimensions

36x124x127mm

*)

WxHxD

*) plus 4mm in depth for the screw terminal

Catalog Numbers

Redundancy 1606-XLSRED40 12-28V Standard unit
Module

Accessory

1606-XLC Wall/panel mount
bracket

Certification Marks

IND. CONT. EQ.

UL 508

UL 60950-1

Class I Div 2

IECEx

ATEX

II 3G Ex nA IIC T4 Gc

Marine

EMC, LVD

Mosfet Redundancy Module