Chapter 1 Connecting program parameters

The following information summarizes the program parameter connection rules.

Standard program to standard program connection rules

The following table summarizes the rules for using program parameters to connect

two standard programs.

Tip: The connection rules for programs also apply to Equipment Phases.

Program_A

(Standard)

Program_B

(Standard)

Input

Output

InOut

Public Controller Scope Tag

(Standard Class)

Input

Yes

Yes

Yes

Output

Yes

Yes*

Yes

Yes

InOut

Yes*

Yes

Yes

Public

Yes

Yes

Yes

Alias

Controller Scope Tag

(Standard Class)

Yes

Yes

Yes

Alias

Alias

* An InOut parameter can only be connected to an Output parameter if the

InOut parameter is configured as a constant.

An Input parameter from Program_A can connect to an Output parameter

of Program_A (wrap around).

Parameters of the same type cannot be connected together.

Public tags can only bind to controller scope tags using an alias.

Program parameter
connection rules

28

Rockwell Automation Publication 1756-PM021A-EN-P - October 2014