Oc_setuppowerfail, Action -75 – Rockwell Automation 1747-PCINT API Software for 1746 I/O User Manual

Page 129

Advertising
background image

OC_SetupPowerFail Action

Library of Routines

6–75

Publication 1747-6.5.3 June 1998

OC_SetupPowerFail
Action

OC_SetupPowerFailAction registers the action to be taken when a power fail
interrupt is received from the scanner.

Syntax:

int OC_SetupPowerFailAction(HANDLE handle, BYTE *bufptr, WORD offset, WORD length, void
(*callback)() );

Parameters:

Description:

You can configure the power failure action in four ways:

No action (default); the power failure interrupt is ignored (

bufptr

is NULL;

callback

is NULL)

Copy a block of data to the host retentive data partition in dual port RAM (

bufptr

points to the data

to save;

callback

is NULL)

Execute a user callback function (

bufptr

is NULL;

callback

points to the routine to call)

Copy a block of data and execute a callback function (

bufptr

points to the data to save;

callback

points to the routine to call)

A system typically has at least 10 milliseconds, and possibly as much as 50 milliseconds or more between
the power fail interrupt and the loss of power. The duration of this interval is a function of the power supply
and system configuration, and it varies from system to system. You might need to experiment to determine
the typical value for a particular system.

Data is copied to the host retentive data partition at the rate of approximately 1K bytes per millisecond.

Declare

bufptr

as static if the OC_SetupPowerFail function is used other than in

main( )

; otherwise

random data will be sent to the host retentive data area.

Parameter:

Description:

handle

Must be a valid handle returned from OC_OpenScanner

bufptr

If

bufptr

is:

NULL

no data is copied (default)

Not NULL

at power fail

length

bytes of data are copied from

bufptr

to the host retentive data partition starting at

offset

.

offset

Specifies the offset within the host retentive data partition to begin copying

length

Number of bytes to copy
If

length

points beyond the end of the host retentive data partition, it is

truncated

callback

If

callback

is:

NULL

no callback function is executed (default)

Not NULL

the power fail interrupt routine calls this function after
copying the data to the host retentive data partition
(if configured)