Library of Routines
OC_SetupPowerFail Action
Publication 1747-6.5.3 June 1998
Return Value:
Considerations:
Supported in the DOS API library only.
Example:
This example is for DOS only.
HANDLE
Handle;
BYTE
buffer1[100];
BYTE
buffer2[100];
int
retcode;
void PowerFailSave( void )
/* power fail callback routine */
{
len = 100;
OC_WriteRtcSRAM( buffer2, 0, &len );
/* Put data in protected area */
}
retcode = OC_SetupPowerFailAction( Handle, buffer1, 0, 100, PowerFailSave );
Name:
Value:
Description:
SUCCESS
0
power fail action was registered successfully
ERR_OCACCESS
2
handle
does not have access to scanner
ERR_OCINIT
5
scanner has not been initialized, see OC_InitScanner
ERR_OCPARAM
8
parameter contains invalid value