Rockwell Automation 1747-PCINT API Software for 1746 I/O User Manual

Page 50

Advertising
background image

5–2

Configuring I/O Modules

Publication 1747-6.5.3 June 1998

struct {

BYTE

mix;

/* Module I/O Mix value */

BYTE

type;

/* Module Type */

BYTE

InputSize;

/* number of inputs in bytes */

BYTE

OutputSize; /* number of outputs in bytes */

WORD

M0Size;

/* size of M0 file in words */

WORD

M1Size;

/* size of M1 file in words */

WORD

GSize;

/* size of G file in words */

WORD

*GData;

/* pointer to array of length GSize words */

char

*Name;

/* pointer to module name string */

} OCSLOTCFG;

You can specify a module by name or by mix and type. You only specify G data if
the module uses G files (such as the 1747-SN). If the

Name

pointer is NULL,

OC_CreateIOConfiguration uses

mix

and

type

to identify the module. See page 4

for the

mix

and

type

values. OC_CreateIOConfiguration supplies the

InputSize

,

OutputSize

,

M0Size

,

M1Size

,

Gsize

, and

Name

fields.

If

Name

points to a string containing a valid module name, the module name

identifies the module. OC_CreateIOConfiguration supplies the

mix

,

type

,

InputSize

,

OutputSize

,

M0Size

,

M1Size

, and

Gsize

fields.

Initialize empty slots and slot 0 with a

mix

value of 0xFF and a

type

value of 0xFF.

If the module is not in the internal database, OC_CreateIOConfiguration doesn’t
alter the OCSLOTCFG.

To support modules not included in the internal database of modules, the host
application can initialize the

mix

,

type

,

InputSize

,

OutputSize

,

M0Size

,

M1Size

, and

GSize

before downloading the I/O configuration to the scanner. See

the I/O module’s user manual to determine the proper configuration information.

After the OC_CreateIOConfiguration and OCGetIOConfiguration functions return,
the I/O configuration structure must be checked for installed modules with G files.
If the

Gsize

field of a non-empty slot configuration is not zero, then the module

contains a G file. If the module contains a G file, initialize

GData

to point to an

array of

Gsize

words to be loaded into the module during scanner configuration.

See the I/O module’s user manual to determine the proper G file data.