Rockwell Automation 1784-KTCX15 INSTL INSTR CONTROLNET COMM. User Manual
Page 12

12
ControlNet Communication Interface Card
Publication 1784-5.33 – September 1997
3. If you are using the card’s default memory address setting, go to step 4.
If you are setting a new base memory address, set the switches to the up or
down position to reflect the selected address from Worksheet C.
20629–M
up (1)
down (0)
Side View
Front View
up (1)
down (0)
1 2
1 2 3 4
D000:0000
Factory-set address
(recommended setting)
Front of Switches
S2
S1
ControlNet Communication Interface Card
25
Publication 1784-5.33 – September 1997
Table A shows the wiring for the cable.
Table A
Wiring for 1786-CP connector cable
Connector 1
Wire Number
Signal Mnemonic
Signal Name
1
ISO-GND
Isolated Ground
2
N.C.
No Connection
3
PTTX-H
Transmit Data High
4
PTTX-L
Transmit Data Low
5
PTRX-L
Receive Data Low
6
PTRX-H
Receive Data High
7
N.C.
No Connection
8
ISO-GND
Isolated Ground
Connector 2
Wire Number
Signal Mnemonic
Signal Name
1
ISO-GND
Isolated Ground
2
N.C.
No Connection
3
PTRX-H
Receive Data High
4
PTRX-L
Receive Data Low
5
PTTX-L
Transmit Data Low
6
PTTX-H
Transmit Data High
7
N.C.
No Connection
8
ISO-GND
Isolated Ground