Set the Station Address on the Base Module
To set the station address, lift the door containing the status LEDs on the top
left side of the module. Adjust the switches located behind the door.
The rotary switches can be set between 00 and 99. Use the adjusting tool
provided in the package, or a small bladed screwdriver to rotate the switches.
The DIP switches are used for addresses between 100 and 125.
ATTENTION
Preventing Electrostatic Discharge
This equipment is sensitive to electrostatic discharge,
which can cause internal damage and affect normal
operation. Follow these guidelines when you handle
this equipment:
• Touch a grounded object to discharge potential
static.
• Wear an approved grounding wriststrap.
• Do not touch connectors or pins on component
boards.
• Do not touch circuit components inside the
equipment.
• If available, use a static-safe workstation.
• When not in use, store the equipment in
appropriate static-safe packaging.