Environmental Specifications

Attribute

Value

Temperature, operating

IEC 60068-2-1 (Test Ad, Operating Cold),
IEC 60068-2-2 (Test Bd, Operating Dry Heat),
IEC 60068-2-14 (Test Nb, Operating Thermal Shock):
0…55 °C (32…131 °F)
Note: Do not connect maximum input voltage
simultaneously to all inputs if the module ambient
temperature is expected to exceed 40 °C.

Temperature, nonoperating

IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold),

IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat),

IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal
Shock):

-40…85 °C (-40…185 °F)

Relative humidity

IEC 60068-2-30 (Test Db, Unpackaged Damp Heat)

5…95% noncondensing

Vibration

IEC 60068-2-6 (Test Fc, Operating):

5 g @ 10…500 Hz

Shock, operating

IEC 60068-2-27 (Test Ea, Unpackaged Shock): 30 g

Shock, nonoperating

IEC 60068-2-27 (Test Ea, Unpackaged Shock): 50 g

Emissions

CISPR 11 (IEC 61000-6-4): Class A

ESD immunity

IEC 61000-4-2:

4 kV contact discharges

8 kV air discharges

Radiated RF immunity

IEC 61000-4-3:

10 V/m with 1 kHz sine-wave 80%AM from
30 MHz…1000 MHz

EFT/B immunity

IEC 61000-4-4:

±2 kV @ 5 kHz on signal ports

Surge transient immunity

IEC 61000-4-5:

±2 kV line-earth(CM) on shielded ports

Conducted RF immunity

IEC 61000-4-6:

10V rms with 1 kHz sine-wave 80% AM from
150 kHz…80 MHz