European hazardous location approval – Rockwell Automation 1794-ID2/B INSTALL INSTR 24v FLEX I/O 2 CHANNEL Incremental Encoder Module User Manual

Page 4

Advertising
background image

4 FLEX I/O 2-Channel Incremental Encoder Module

Publication 1794-IN063C-EN-E - February 2014

European Hazardous Location Approval

The following module is European Zone 2 approved: 1794-ID2 Series B.

The following applies when the product bears the Ex Marking
European Zone 2 Certification (The following applies when the product bears the Ex Marking)
This equipment is intended for use in potentially explosive atmospheres as defined by European
Union Directive 94/9/EC. DEMKO certifies that this equipment has been found to comply with the
Essential Health and Safety Requirements relating to the design and construction of Category 3
equipment intended for use in Zone 2 potentially explosive atmospheres, given in Annex II to this
Directive.
Compliance with the Essential Health and Safety Requirements has been assured by
compliance with EN 60079-15:2012 and EN 60079-0:2010.

WARNING: Observe the following additional Zone 2 certification
requirements:

This equipment is not resistant to sunlight or other sources of UV
radiation.

This equipment must be installed in an enclosure providing at least IP54
protection when applied in Zone 2 environments.

This equipment shall be used within its specified ratings defined by
Rockwell Automation.

Provision shall be made to prevent the rated voltage from being
exceeded by transient disturbances of more than 40% when applied in
Zone 2 environments.

Secure any external connections that mate to this equipment by using
screws, sliding latches, threaded connectors, or other means provided
with this product.

Do not disconnect equipment unless power has been removed or the
area is known to be nonhazardous.

Advertising