Rockwell Automation 1757-PROCESSLINX ProcessLinx OPC Server to Server Software User Manual User Manual

Page 13

Advertising
background image

Publication 1757-UM002B-EN-P - January 2003

Setup Procedures 1-5

2. Type regsvr32 opcproxy.dll in the Run dialog box.

3. On the server machine, go to the

C:\Honeywell\Client\Opcserverconnect, folder and copy the
HSCOPCCONNECT.REG & HSCOPCSERV.REG files to a floppy
diskette.

4. On the ProcessLinx Client machine, create a directory called

C:\Honeywell\Client.

5. Copy the hscopcconnect.reg file and the hscopcServ.reg file from the

floppy, to the C:\Honeywell\Client directory of the ProcessLinx Client.

6. Using Notepad, open then edit the hscopcconnect.reg file.

7. Edit line#19 section. Change the entry

from: @=”d:\\hwiac\\programs\\tps\\hci\\hscopcserv.exe

to: @=”c:\honeywell\client\hscopcserv.exe

8. Go into the C:\Honeywell\Client directory on the Client.

9. Run (double-clicking) each of the .REG files in Step 3,

HSCOPCCONNECT.REG & HSCOPCSERV.REG, one at a time.

All registry changes that tell the Client, the Servers GUID have now
been made to the registry.

IMPORTANT

Unless opcproxy.dll is in the Windows\System32 directory
the above command will fail because it can't find the
OPCPROXY.DLL. You need to specify the full path the
the DLL (i.e. regsvr32 “C:\Program Files\Common
Files\OPC Foundation\opcproxy.dll”)

Advertising