Rockwell Automation 1788-EN2DN Ethernet-to-DeviceNet Linking Device User Manual
Page 30

30 Ethernet-to-DeviceNet Linking Device
Rockwell Automation Publication 1788-IN055C-EN-P - September 2011
10.
Select the Output tab.
The Output mapping dialog box is displayed.
11.
Click Apply, and click Yes to download the scanlist to the linking
device.
12.
Click OK.
(Optional) Add the Linking Device to an RSLogix 5000 Software Project
1.
Create a new project in RSLogix 5000 software by selecting File>New.
You see the New Controller dialog box.
2.
From the Type pull-down menu, choose the controller type.
TIP
The linking device starts scanning as soon as it finds entries in its scanlist.
However, in Idle mode, output data will not be sent to the devices.
The top portion of this dialog box gives a list
of the devices in the scan list to which the
linking device will send output data. The
bottom shows the location in the Output
table where the data will be placed for each
device. This shows the format of the Output
table of the linking device. This is the format
of the output data that will be sent to the
linking device from the EtherNet/IP scanner.