Troubleshoot with the indicators – Rockwell Automation 1792D-OVT16E ArmorBlock MaXum 16 Sinking Output Module, Series B User Manual

Page 10

Advertising
background image

10 ArmorBlock MaXum 16 Sinking Output Module Series B

Publication 1792D-IN041B-EN-P - September 2000

Troubleshoot with the Indicators

This module has the following indicators:

• Net/Mod status indicator

• Logic status indicator

• Auxiliary power

• Individual point status indicators

The following table describes network and module status indicators.

Net/Mod Status Indicator

Indicator

Status

Off

No power or auto bauding

Flashing Green/Off On line but not connected

Solid Green

On line, link OK, connected

Flashing Red

Recoverable fault - module configuration error

I/O connection fault - one or more I/O connections in the timed-out
state

42048

Point LED Indicators for

Connector A

Connector H

Connector B

Connector G

Outputs 2 and 3

Point LED Indicators for

Outputs 12 and 13

Module Status Indicators

LED Assignments

Connector C

Connector D

Outputs 6 and 7

Connector F

Outputs 10 and 11

Connector E

Outputs 8 and 9

Outputs 0 and 1

Outputs 14 and 15

Outputs 4 and 5

Advertising