Programming Overview 4-7

Refer to the BASIC Language Reference Manual, publication
1747-RM001, for additional information on these statements.

( ) .OR. ( )

Combine the first expression with the second expression
using .OR..

2.OR.1

( ) .XOR. ( )

Combine the first expression with the second expression
using .XOR..

3.XOR.2

MTOP

Return last valid memory address.

PRINT MTOP

( ) * ( )

Multiply expressions together.

4*4

p

Store constant.

3.1415926

RND

Return a random number.

RND

SGN ( )

Return the sign of argument.

SGN (-5)

SIN ( )

Return the sine of argument.

SIN (3.14)

SQR ( )

Return the square root of the argument.

SQR (100)

( ) - ( )

Subtract one expression from another.

8-4

TAN ( )

Return the tangent of argument.

TAN (.707)

TCON

Read/assign TCON register.

TCON=10H

TIME

Read/assign the free running clock.

P. TIME

XBY ( )

Read/assign external data memory.

P. XBY (10)

( ) = ( )

Allow the first expression to equal the second expression. 10=10

( ) < ( )

Allow the first expression to be less than the second
expression.

9<10

( ) <= ( )

Allow the first expression to be less than or equal to the
second expression.

X<=10

( ) > ( )

Allow the first expression to be greater than the second
expression.

10>9

( ) >= ( )

Allow the first expression to be greater than or equal to
the second expression.

X>=10

( ) <> ( )

Allows the first expression to be unequal to the second
expression.

10<>9

Operator

Function

Examples

Advertising