Protected AC Output Module

8

Publication 1771-IN077A-EN-P - October 2002

You can use an output of the 1771–OP module to drive an input of a
120V AC input module (1771–IA, –IA2, –ID and –IAD) to indicate
status, such as the turning on a motor starter (Figure 2). Both
modules must be powered by the same ac source. In addition, you
must add an external resistor between the output terminal and the
common (L2) (Figure 2). Typically, this is a 2.5K ohm, 10W resistor.

Figure 2

Using an Output Module to drive an Input Module

L1

2.5K ohm

10 Watt

Resistor

A
O
1
2
3
4

5
6
7
B

L1

A
O
1
2
3
4

5
6
7
B

L2

L2

Typically

ac Low

ac High

Protected AC (120V) Output Module

1771-IA

AC (120V) Input Module

1771-OP

L1

2.5K ohm

10 Watt

Resistor

A
O
1
2
3
4

5
6
7
B

L1

L2

Typically

ac High

Protected AC (120V) Output Module

1771-OP

AC/DC (120V) Input Module

1771-IAD

L2

ac Low