North american hazardous location approval – Rockwell Automation 1791D-N4CV2X CompactBlock I/O for DeviceNet Expansion Module I.I. User Manual

Page 18

Advertising
background image

18 CompactBlock I/O Analog Combination Input/Output Expansion Module

Publication

1791D-IN002A-EN-P - June 2003

North American Hazardous Location Approval

The following information applies when operating
this equipment in hazardous locations:

Informations sur l’utilisation de cet équipement en
environnements dangereux :

Products marked “CL I, DIV 2, GP A, B, C, D” are suitable
for use in Class I Division 2 Groups A, B, C, D, Hazardous
Locations and nonhazardous locations only. Each product
is supplied with markings on the rating nameplate
indicating the hazardous location temperature code.
When combining products within a system, the most
adverse temperature code (lowest “T” number) may be
used to help determine the overall temperature code of
the system. Combinations of equipment in your system
are subject to investigation by the local Authority Having
Jurisdiction at the time of installation.

Les produits marqués "CL I, DIV 2, GP A, B, C, D" ne
conviennent qu’à une utilisation en environnements de
Classe I Division 2 Groupes A, B, C, D dangereux et non
dangereux. Chaque produit est livré avec des marquages sur
sa plaque d’identification qui indiquent le code de
température pour les environnements dangereux. Lorsque
plusieurs produits sont combinés dans un système, le code
de température le plus défavorable (code de température le
plus faible) peut être utilisé pour déterminer le code de
température global du système. Les combinaisons
d’équipements dans le système sont sujettes à inspection
par les autorités locales qualifiées au moment de
l’installation.

!

WARNING

EXPLOSION HAZARD

• Do not disconnect

equipment unless power
has been removed or the
area is known to be
nonhazardous.

• Do not disconnect

connections to this
equipment unless power
has been removed or the
area is known to be
nonhazardous. Secure any
external connections that
mate to this equipment by
using screws, sliding
latches, threaded
connectors, or other means
provided with this product.

• Substitution of components

may impair suitability for
Class I, Division 2.

• If this product contains

batteries, they must only be
changed in an area known
to be nonhazardous.

AVERTISSEMENT

!

RISQUE D’EXPLOSION

• Couper le courant ou

s’assurer que
l’environnement est classé
non dangereux avant de
débrancher l'équipement.

• Couper le courant ou

s'assurer que
l’environnement est classé
non dangereux avant de
débrancher les
connecteurs. Fixer tous les
connecteurs externes
reliés à cet équipement à
l'aide de vis, loquets
coulissants, connecteurs
filetés ou autres moyens
fournis avec ce produit.

• La substitution de

composants peut rendre
cet équipement inadapté à
une utilisation en
environnement de Classe I,
Division 2.

• S’assurer que

l’environnement est classé
non dangereux avant de
changer les piles.

Advertising