6 ArmorBlock MaXum 4 Input / 4 Output Module Series B

Publication 1792D-IN012B-EN-P - September 2000

Connect the Input / Output Cord Sets to the MaXum
Module

This module uses 5 pin micro (12mm) style PCB mounted connectors.

Four micro caps cover the connectors on your module. Remove the
caps and connect your cord sets to the appropriate ports. This
product has two inputs or outputs per I/O connector. Use a “Y”
splitter cable for access to all I/O connections.

Use the micro caps to cover and seal unused ports. Pinout diagrams
for the connectors are shown next.

Please refer to publication 889-5.0 for Rockwell Automation cables

and cord sets offerings.

IMPORTANT

If the devices (sensors) connected to the input
connections require Class 2 power to operate, the
DeviceNet connections of this equipment must be
powered by a Class 2 source.

Input Micro-Connector

(View into Sockets)

Pin 1 Sensor Source Voltage
Pin 2 Input B

Pin 3 Return Logic Ground

1

Pin 4 Input A
Pin 5 Not Used

1

5

3

4

2

41452

Output Micro-Connector

(View into Sockets)

Pin 1 Not Used
Pin 2 Output B
Pin 3 Auxiliary Power Ground
Pin 4 Output A
Pin 5 Not Used

1

Logic Ground is approximately 0.4V above DeviceNet V-measured at the module.

1

5

3

4

2