Preventing electrostatic discharge, Set the node address – Rockwell Automation 1788-DNBO DeviceNet Daughtercard Installation Instructions User Manual

Page 5

Advertising
background image

DeviceNet Daughtercard 5

Publication 1788-IN053A-EN-P - December 2001

Preventing Electrostatic Discharge

Set the Node Address

You must set two switches to configure the daughtercard with its unique network address.
Figure 1 shows the location of the switches. These switches are read on powerup to establish
the network address of the card.

Set the node address to a value between 00 and 63. The node address of the daughtercard
must be unique to the other nodes on your DeviceNet network.

Figure 1 - Set the Node Address and Network Baud Rate

ATTENTION

!

Preventing Electrostatic Discharge
This equipment is sensitive to electrostatic discharge, which can cause
internal damage and affect normal operation. Follow these guidelines
when you handle this equipment:

• Touch a grounded object to discharge potential static.
• Wear an approved grounding wriststrap.
• Do not touch connectors or pins on component boards.
• Do not touch circuit components inside the equipment.
• If available, use a static-safe workstation.
• When not in use, store the equipment in appropriate static-safe

packaging.

IMPORTANT

Setting the node address to 99 and cycling power to the host will cause
the daughtercard to erase its scanlist. Set the node address to 99 only if
you want to erase the scanlist.

31288-M