10 ControlLogix SERCOS interface Module

Publication

1756-IN572G-EN-P - May 2005

Table 3 Module Health and Communication Status (OK) Indicator

State

Description

Recommended Action

Off

The module is not operating.

• Apply chassis power.
• Verify the module is completely

inserted into the chassis and
backplane.

Flashing Green

The module has passed internal
diagnostics, but has not
established active
communications.

None, if you have not configured
the module.

Solid Green

• Data is being exchanged.
• The module is in the normal

operating state.

None. The module is ready for
action.

Flashing Red

• A major recoverable failure has

occurred.

• An NVS update is in progress.

If an NVS update is in progress,
complete the NVS update.

If an NVS update is not in
progress: Reboot

Solid Red

A potential nonrecoverable fault
has occurred.

• Reboot the module.
• If the solid red persists, replace

the module.