Connect the Fiber Optic Cables

ControlLogix SERCOS interface modules use fiber optics that are rated Class
1 for IEC LED safety classification. Under most viewing conditions, there is
no eye hazard.

1. Remove the protective end caps from the receiver and transmitter

ports.

ATTENTION

You must give a unique address to each drive on the SERCOS
ring. If you give 2 drives the same address on the same ring, both
drives respond to commanded motion. This could injure people
or damage equipment.

ATTENTION

Under certain conditions, viewing the optical port may expose
the eye to hazard. When viewed under some conditions, the
optical port may expose the eye beyond the maximum
permissible exposure recommended in ANSI Z136.2, 1993.