Specifications – Rockwell Automation 1771-OAD AC(12-120V)Output Installation Instructions User Manual

Page 14

Advertising
background image

Specifications

AC (12-120V) Output Module

14

Publication 1771ĆIN024B-EN-P - November 2002

Outputs per Module

16

Module Location

1771ĆA1B through ĆA4B or later I/O chassis, 1771ĆAM1, ĆAM2 chassis

Output Voltage Range

10 to 138V ac @ 47 Ć 63Hz

Output Current Rating

2A per output - not to exceed8A per module

Surge Current (maximum)

25A per output for 100ms, repeatable every 1 second

25A per module for 100ms, repeatable every 1 second

Minimum LoadCurrent

5mA per output

On State Voltage Drop (max.)

1.5V at loadcurrent > 50mA

5.8V at loadcurrent < 50mA

Off State Leakage Current (max.)

3.0mA per output @ 138V ac

Signal Delay (max.) Off to On

On to Off

Zero crossing 8.3ms @ 60Hz, 10.0ms @ 50Hz

Zero crossing 8.3ms @ 60Hz, 10.0ms @ 50Hz

Power Dissipation

13 Watts (max.), 1.5 Watts (min.)

Thermal Dissipation

48.0 BTU/hr (max.), 5.13 BTU/hr (min.)

Backplane Current

295mA

Isolation Voltage

Testedto 2500V dc for 1s

Conductors

Wire Size

Category

14-22AWG (2.5-0.25mm

2

) strandedcopper wire ratedat 75

o

C or

greater

1

3/64 inch (1.2mm) insulation (max)

2

2

Environmental Conditions

Operating

Temperature

IEC 60068-2-1 (Test Ad, Operating Cold)

IEC 60068-2-2 (Test Bd, Operating Dry Heat)

IEC 60068-2-14 (Test Nb, Operating Thermal Shock)

32 to 140°F (0

o

to 60

o

C)

Storage Temperature

IEC 60068-2-1 (Test Ab, Unpackaged, Nonoperating Cold)

IEC 60068-2-2 (Test Bb, Unpackaged, Nonoperating Dry Heat)

IEC 60068-2-14 (Test Na, Unpackaged, Nonoperating Thermal Shock)

-40 to 185°F (-40 to 85

o

C)

Relative Humidity

IEC 60068-2-30 (Test Db, Unpackaged, Nonoperating Damp Heat)

5 to 95%, noncondensing

Shock

Operating

Nonoperating

IEC 60068-2-27 (Test Ea, UnpackagedShock)

30g

50g

Vibration

IEC 60068-2-6 (Test Fc, Operating)

2g @ 10-500Hz

ESD Immunity

IEC 61000-4-2

4kV indirect discharges

Radiated RF Immunity

IEC 61000-4-3

10V/m, with 1kHz sine-wave 80% AM from 30MHz to 1000MHz

EFT/B Immunity

IEC 61000-4-4

+1kV @ 5kHz on signal ports

Surge Transient Immunity

IEC 61000-4-5

+1kV line-line (DM) and+2kV line-earth (CM) on signal ports

Conducted RF Immunity

IEC 61000-4-6

10V rms with 1kHz sine wave 80% AM from 150kHz to 30MHz

Emissions

CISPR 11

Group 1, Class A (with appropriate enclosure)

Specifications continued on next page.