5–2

Operating the Scanner

Each scanner has a multi-position rotary switch which lets you adjust
the scan angle

to

!@2, #@4,

or maximum angle.

Catalog No. 2755-LD4 A,B,C

Catalog No. 2755-LD4 E

Catalog No. 2755-LD8

Setting

Nominal

Scan Angle

Setting

Nominal

Scan Angle

Setting

Nominal

Scan Angle

!@2

25

_

!@2

20

_

!@2

15

_

#@4

37.5

_

#@4

30

_

#@4

22.5

_

MAX

50

_

MAX

40

_

MAX

30

_

The scan angle adjustment switch is located behind a

!@4

-20 cover

screw (with gasket) on the back of the scanner. This cover screw is
necessary to maintain a NEMA Type 4 rating. After making the scan
angle adjustment, the cover screw must be tightened to 20 inch-lbs.

!

ATTENTION: The enclosure is not completely
sealed without the scan angle adjustment screw. Dust
and moisture may enter the enclosure causing
deterioration in performance.

Figure 5.1
Scan Angle Adjustment Switch

Back View

SCAN 6

POWER

VALID

Scan Angle

Adjustment Switch

Cover Screw

Scan Angle Adjustment