Maintenance and Troubleshooting

Problem: “Power” indicator lights but the laser beam is not on.

Cause:

Decoder setup parameters are not set up
properly.

Solution:

Verify decoder configuration.

Cause:

Package detector not operating.

Solution:

Verify decoder configuration / package
detect operation.

Cause:

Laser scanning mechanism is not
operating correctly.

Solution:

Return scanner to Allen-Bradley for
service.

Problem:

Unable to read a label.

Cause:

Decoder not configured correctly.

Solution:

Check decoder configuration to verify that
parameters are set appropriately for your
application. After making changes, SAVE
configuration to EEPROM and restart
decoder.

Cause:

Label(s) out of specification.

Solution:

Use good quality labels that are within
specifications.

Cause:

Scan window is dirty.

Solution:

Clean window as described in previous
sections of this chapter.

Cause:

Scanner is at incorrect angle or distance
from bar code symbols.

Solution:

Check that the scanning distance is correct
and orientation of labels to scanner is
correct.

Determine the optimum reading angle by
using a static bar code label position and
checking the decoder performance
indicators with the Decode Mode set to
Continuous. Refer to ”Compensating
for Pitched Symbols”.

Fix the scanner at a position that results in
a high decoder performance value. After
properly positioning the scanner, return
the decoder configuration to the correct
operating mode.