Rockwell Automation 57C428 Toledo Scale Interface Module User Manual

Page 21

Advertising
background image

4Ć5

Register 66 contains status byte A". Refer to figure 4.8.

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

bits

register 66

- - - - - - - - - R 1

R R R R R

Decimal pt.

Location
0 = x100

1 = x10

2 = x1

3 = x.1

4 = x.01

5 = x.001

6 = x.0001

7 = x.00001

Model

Dependent

Model

Dependent

Model

Dependent

Figure 4.8Ć Status Byte A"

Register 67 contains status byte B". Refer to figure 4.9.

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

bits

register 67

- - - - - - - - - R 1

R R R R R

Mode

0 = Gross

1 = Net

Model Dependent

Units

0 = pounds

1 = kilograms

Motion

0 = no motion

1 = in motion

Range

0 = in range

1 = overrange

Weight is

0 = Positive

1 = Negative

Figure 4.9Ć Status Byte B"

Advertising