Rockwell Automation 2706-ND1 DL40 OFFLINE PROGRAMMING SFTWR.USER MANUAL User Manual
Page 104

Chapter 6
The Transfer Menu
6 – 16
If you choose
ETHERNET
, you must then specify an IP Address in the
appropriate field. IP Addresses take the following form:
X.X.X.X
where X is a decimal number from 0 through 255. Consult your network
administrator to obtain an IP Address.
Setting Device Parameters for a DH+ Network
Additional transfer parameters may be necessary when you select DH+
communications devices. For card numbers 1784-KT, 1784-KT2, 1784-KL,
1784-KTX, and 1784-PCMK devices, you must specify the
DH+
Connection Type
and
DH+ Network Access
.
Figure 6.12
1784-KT, KTX, PCMK configuration screen for DH+ network
Parameter
Acceptable values
DH+ Connection Type
Direct
Multidrop
DH+ Network Access
Local
Remote (Bridge)
DH+ Connection Type
Select
Direct
if your programming computer and your PLC-5 are the only
devices on the DH+ link, or if there are multiple devices on the link and your
programming computer is the first or the last physical device on the link.
Select
Multidrop
if there are multiple devices on the link and your
programming computer is not first or last physical device on the link.