Product Overview

Feedback Board

The feedback board receives status information from the drive
components, scales it to a signal level, and supplies it to the main
control board (through the power stage interface board).

Figure 1.7
Feedback Board

The feedback board has terminals for the 3-phase AC inputs (A, B,
and C) and for the armature power (VA+ and VA-), a series of jumper
connections to adjust for AC input voltage, jumper connections for
the field current, a bus connection to the power stage interface board,
two terminals blocks for placing burden resistors in parallel to the
circuit, and a Phoenix connection terminal block connected to other
drive components.

Note: Jumper settings are defined in the installation chapter of
this manual.

24V DC Power Supply

There are three 24V DC power supply units that may be installed in
the drive. There is a feedback board supply, an optional air flow
sensor supply, and an optional control board supply (used to power an
optional adapter board). These supply units are fed from the 115V
AC control power circuit.

576VAC

TO

690VAC

301VAC

TO

575VAC

150 VAC

TO

300 VAC

150 VAC

TO

300 VAC

301VAC

TO

575VAC

576VAC

TO

690VAC

150 VAC

TO

300 VAC

J40

576VAC

TO

690VAC

150 VAC

TO

300 VAC

301VAC

TO

575VAC

576VAC

TO

690VAC

301VAC

TO

575VAC

150 VAC

TO

300 VAC

T B 2

T B 3

FEEDBACK BURDEN RESISTOR

FEEDBACK BURDEN RESISTOR ARMATURE

A

B

C

VA+

TB 1

(1)

(2)

(3)

(4)

301VAC

TO

575VAC

576VAC

TO

690VAC

VA-

To Pow er S tag e

In terfac e B oar d

N ot U sed

Ju m p er C onn ection

(Field C ur rent)

Ju m p er C onn ections

(A C In pu t V oltag e)

Advertising