Options – Rockwell Automation 1395 Digital DC Drive User Manual

Page 82

Advertising
background image

Publication 2361-5.01 July 1998

B-4

Catalog Numbers and Spare Parts Kits

Control Power Source

6P = Standard capacity control transformer with primary fusing
6TB = 115V AC control power, factory wired from 115V AC control bus to drive unit
6SC = 115V AC control power supplied by others

Door-Mounted Pilot Lights

4R = Power-on

Door-Mounted Switches

3 = Speed 0-1-2 selector
760A = Single-turn speed pot

Unit Door Nameplates

M3EW = White background with black lettering; phenolic label
N3EB = Black background with white lettering; phenolic label
N3ER = Red background with white lettering; phenolic label

Miscellaneous

14WLBL = Brady Datab ™ wire labels
J12 = 115V DC, 15A duplex receptacle, customer-wired
J11 = Audio phone jack

Drive Port A Cards

14DAA = Discrete adapter, 115V AC
14DAD = Discrete adapter, 24V DC with 0.5A, 24V power supply
14DRA = Digital reference adapter, 24V DC with 0.5A, 24V power supply

Configuration Terminals

766 = Door-mounted D-shell connector
766A = Door-mounted DHT (Standard Terminal)
766B = Door-mounted EHT (Enhanced Terminal)

Door-Mounted Pushbuttons

1B = Drive stop
1JF = Jog forward
1JR = Jog reverse
1ES = Hardwared stop interface

Door-Mounted Illuminated
Pushbuttons

5G = Start / Running
5A = Clear faults / Drive faulted

Drive Port B Cards

14CN = ControlNet adapter
14NA = Node adapter
14MCA = Multi-communications adapter

Options

Tachometer Feedback
Scaling Boards

14T033 = Scaling board for resolvers with output voltages of 0-33V DC
14T046 = Scaling board for resolvers with output voltages of 34-46V DC
14T070 = Scaling board for resolvers with output voltages of 47-70V DC
14T125 = Scaling board for resolvers with output voltages of 71-125V DC
14T178 = Scaling board for resolvers with output voltages of 126-178V DC
14T250 = Scaling board for resolvers with output voltages of 179-250V DC

Dynamic Braking Contactor

14DB = Dynamic braking contactor option





















Auxiliary Contacts

Protection

14LSP = Line RC suppressor module
14AFL = Air flow loss switches

989X = (2) Normally open and (2) normally closed contactors mounted internally if 1250/1650A

OR

(4) Normally open and (4) normally closed contactors mounted internally if 3000A unit

Blower Starters

14BN = (1) NEMA size 1 FVNR starter assembly with 30A fuse blocks mounted within the drive unit
14B2N = (2) NEMA size 1 FVNR starter assembly with 30A fuse blocks mounted within the drive unit
14B2NX = (2) NEMA size 2 FVNR starter assembly with 60A fuse blocks mounted within the drive unit
14BI = (1) IEC, 24A starter assembly mounted with 30A fuse blocks within the drive unit
14B2I = (2) IEC, 24A starter assembly mounted with 30A fuse blocks within the drive unit
14B2IX = (2) IEC, 30A starter assembly mounted with 60A fuse blocks within the drive unit

Input Option

14HBC = AC power input is wired from the horizontal thru-bus to the circuit breaker

Field Supply Upgrade

14FX = Field supply upgrade for fields requiring 43 to 90A

Field Voltage Step-Down
Options for Units with 575
or 660V AC Inputs

14SD28 = Field transformer for field currents up to 28A
14SD40 = Field transformer for field currents up to 40A
14SD90 = Field transformer for field currents up to 90A