Rated armature and field currents, Rated armature and field currents -2 – Rockwell Automation 1395 Digital DC Drive User Manual

Page 68

Advertising
background image

Publication 2361-5.01 July 1998

6-2

Starting Up Your Drive

Table 6.D: Voltage Measurements (1250, 1650, 3000A Drives)

Rated Armature and Field Currents

Armature and field current ratings are listed in the electrical
specifications in Appendix A.

Test Points

Expected Voltage

Measured Voltage

AC Voltages

L1 to L2

Rated AC Input

L2 to L3

Rated AC Input

L3 to L1

Rated AC Input

TB8-1 to TB8-2

Rated DC Field Output

TB5-3 to TB5-12

115V AC (±10%)

Main Control Board

TP51 to TP52

+5V DC (±0.15V)

TP55 to TP57

+12V DC (±0.48V)

TP56 to TP57

-12V DC (±0.48V)

TP58 to TP53

+5V DC (±0.15V)

TP54 to TP53

+12V DC (±0.48V)

Power Stage Interface Board

TP1 to TP7

+24V DC (±6V)

Advertising