Upgrading the boot code firmware – Rockwell Automation 6180 Keypad Configuration Utility Floppy Disk Drivers (for 6180 Industrial Computer User Manual

Page 23

Advertising
background image

Keypad Configuration Utility

23

Upgrading the Boot Code Firmware

This section shows how to upgrade the boot code firmware (*.BOO)
stored on the KIC Card. Upgrading of the boot code firmware is not
normally required, even if the application code firmware is
upgraded.

Upgrading the boot code firmware on the KIC card requires:

setting the P2 jumper to the correct position on the KIC card.

downloading the boot code *.BOO file to the KIC card.

Note: You cannot edit the boot code firmware file (*.BOO).
Allen-Bradley supplies this file when an upgrade of the KIC card is
required.

Setting the P2 Jumper

When upgrading the boot code firmware, the P2 jumper on the KIC
card (in the computer) must be in the Normal position. The position
of the P2 jumper and its location on the KIC card is shown below.

P1

P2*

P1

P2

Normal Position (Default)
Allows download of boot
code firmware using the
Keypad Configuration
Utility.

Hard disables write
protection of boot
block code.

KIC Card Keyboard Port

Default Position
Keypad Keys Enabled

Keypad Keys
Disabled

* Note: Removing Jumper P2 from the board enables write
protection. With write protection enabled, the Keypad Configu-
ration Utility cannot write to the KIC boot code.

Advertising