Environmental, Certifications – Rockwell Automation 6181F_P Series E Integrated Display Computers Installation Instructions User Manual

Page 23

Advertising
background image

Industrial Integrated Display Computers 23

Rockwell Automation Publication 6181P-IN010F-EN-P - July 2013

Environmental

Attribute

6181F, 6181P

Temperature, operating

(1)

All Standard models
Non-display
1200P and 1500P Performance
1700P Performance

0…50 °C (32…122 °F)
0…55 °C (32…131 °F)
0…55 °C (32…131 °F)
0…50 °C (32…122 °F)

Temperature, nonoperating

(1)

-20…60 °C (-4…140 °F)

Relative humidity

10…90% noncondensing

Altitude, operating

2000 m (6561 ft)

Altitude, nonoperating

12,000 m (40,000 ft)

Shock, operating

(1)(2)

15 g (1/2 sine, 11 ms)

Shock, nonoperating

(1)(2)

30 g (1/2 sine, 11 ms)

Vibration, operating

(1)(2)

6181F
6181P

0.012 in. p-p, (10…57 Hz); 2 g peak, (57…640 Hz)
0.006 in. p-p, (10…57 Hz); 1 g peak, (57…640 Hz)

Vibration, nonoperating

(1)(2)

0.012 in. p-p, (10…57 Hz); 2 g peak, (57…640 Hz)

(1)

The optical disc drive (ODD) is considered a maintenance device. Therefore, do not operate computers with ODDs in temperatures above 45 °C
(113 °F) or in environments with the shock and vibration levels listed.

(2)

Applies only to panel mounted display computers and wall mounted non-display computers.

Certifications

(1)

Attribute

6181F, 6181P

c-UL-us

UL/c-UL Listed per UL 60950-1 and CSA C22.2 No. 60950-1-03

CE

Marked for all applicable directives
EMC 2004/108/EC
LVD 2006/95/EC

C-Tick

Australian Radiocommunications Act, compliant with:
AS/NZS CISPR 11; Industrial Emissions

RoHS

China RoHS
Turkey RoHS (EEE Yönetmeliğine Uygundur. In Conformity with the EEE Regulation)

(1)

See

http://www.rockwellautomation.com/rockwellautomation/certification/overview.page

for declarations of conformity, certificates, and other

certification details.