Industrial Integrated Display Computers 3

Rockwell Automation Publication 6181P-IN010F-EN-P - July 2013

Precautions

Read and follow these precautions for use.

Environment and Enclosure Information

European Union Directive Compliance

This computer meets the European Union Directive requirements when installed within the
European Union or EEA regions and have the CE mark. A copy of the Declaration of
Conformity (DoC) is available at

http://www.rockwellautomation.com/rockwellautomation/certification/overview.page

.

ATTENTION: This equipment is intended for use in a Pollution Degree 2 industrial environment, in
overvoltage Category II applications (as defined in IEC publication 60664-1), at altitudes up to
2000 m (6561 ft) without derating.

This equipment is considered Group 1, Class A industrial equipment according to IEC/CISPR 11. Without
appropriate precautions, there may be difficulties with electromagnetic compatibility in residential and
other environments due to conducted and radiated disturbances.

UL listed equipment need not be mounted inside another enclosure if NEMA Type and IEC ratings
are not required, but the mounting method must limit the tilt of the computer to no more than 60°
from vertical. An example is a tabletop stand. The mounting means must be firmly attached to the
supporting surface using screws, bolts, or clamps so the computer cannot tip. These computers
ship with a gasketed bezel to meet specified NEMA and IEC ratings only when mounted in a panel
or enclosure with an equivalent rating. Subsequent sections of this publication may contain
additional information regarding specific enclosure type ratings that are required to comply with
certain product safety certifications.

In addition to this publication, see the following:

Industrial Automation Wiring and Grounding Guidelines, publication

1770-4.1

, for additional

installation requirements

NEMA Standard 250 and IEC 60529, as applicable, for explanations of the degrees of protection
provided by enclosures

ATTENTION: This equipment is intended to operate in an industrial or control room environment,
which uses some form of power isolation from the public low-voltage mains. Some computer
configurations may not comply with the EN 61000-3-2 Harmonic Emissions standard as specified
by the EMC Directive of the European Union. Obtain permission from the local power authority
before connecting any computer configuration that draws more than 75 W of AC power directly
from the public mains.

To comply with EN 55024, the Ethernet port LAN cable must be less than 30 m (98.42 ft). All other
I/O cables must be less than 3 m (9.84 ft) and only used indoors; these cables must not exit the
building at any point.