Specifications, Electrical – Rockwell Automation 2705-APG RediPanel Plug and Go Products User Manual
Page 21

Bulletin 2705
RediPANEL 800A Push Button Modules
User Manual
21
Lamp Replacement (cont’d)
ЛЛ
ЛЛ
ЛЛ
ЛЛ
ООО
О
О
Л
Л
Л
Л
Л
ООО
О
О
ОО
ОО
ООО
ООО
ЛЛ
ЛЛ
ЛЛ
ЛЛ
ЛЛ
ОО
ОО
Л
ОО
STEP 1
STEP 2
800M-N5
3. Carefully insert the new lamp into the socket.
!
ATTENTION: Before replacing the lens carrier into the push
button, be sure the lamp is seated properly or a short may result.
The LED must be installed with plus (+) indicator facing to the
left.
4. Replace the keyed lens carrier into the push button.
5. Check for proper operation of the push button.
Electrical
External Power Supply
24 Volts DC
"10 %
21.6-26.4 VDC
Input Current and
Power Ratings
(All On)
32 Buttons 16 Buttons
SLC .95 Amps
.47 Amps
PLC 1.23 Amps
.55 Amps
LEDs
24 VDC six chip cluster lamps
Catalog No. 800T-N62R (red)
-N62G (green)
-N62A (amber)
Power Connector
Two position header (part of printed circuit board
assembly) and two position removable connector
(provided). End user responsible for wiring between
connector and external power supply.
UL File/Guide
Non-Hazardous Locations: E56639/NMTR
CSA
Non-Hazardous Locations: LR62923
Specifications