ControlNet Message/Traffic Generator Tool

34

Publication 9220-10.1 — July 1996

/*****************************************************************\
**

** Name: MG_SendUnconnectedMsg ( )

**
** Description:
** This function sends an unconnected ASA message from the
** configuration file.
**
** Inputs: USINT *message

– Message to be sent.

**
** Outputs: UINT status

– SUCCESS

**
** Copyright (c) 1995, ‘96 Allen–Bradley Company
**
\*****************************************************************/

/*****************************************************************\
**

** Name: MG_ReceiveUnconnected ( )

**
** Description:
** This function receives an unconnected ASA message from the UCMM.
**
** Inputs:

USINT *message

– Pointer to where to put the

**

received message.

**

UINT *dataSize

– Size, in bytes, of the

**

message received.

**
** Outputs:

UINT status

– SUCCESS if message received

**

– FAILURE if no message received

**
** Copyright (c) 1995, ‘96 Allen–Bradley Company
**
\*****************************************************************/

/*****************************************************************\
**

** Name: MG_SendConnected ( )

**
** Description:
** This function sends a user provided message on a Connection
** previously opened with a call to MG_OpenConnection.
**
** Inputs

UINT connIndex – Connection index that was returned

**

by the MG_OpenConnection function.

**

USINT *message – Message to be sent.

**

UINT dataSize – Size, in bytes, of the message to

**

be sent.

**
** Outputs: UINT status

– SUCCESS

**
** Copyright (c) 1995, ‘96 Allen–Bradley Company
**
\*****************************************************************/