Running the Demo Unit

4-1

C

HAPTER

4

Running the Demo Unit

The demo consists of three step-by-step labs to acquaint you
with the basic operation of the drive.

Purpose of the labs:

4.1

The Labs

Lab A: Reset the drive to factory defaults using the
following procedure.

Tools required: None

Step 1. Turn on the demo unit using the power switch.

Step 2. If a parameter number is not displayed, press the

PROGram key.

Step 3. Press

or

until b - - is displayed.

Step 4. Press PROGram to select the b parameter group.

Step 5. Press

or

until parameter b84 is displayed.

Step 6. Press PROGram to display the value of b84.

Step 7. Press

or

until 00 is displayed.

Step 8. Press to save the displayed value. b84 is

displayed again.

Lab A

Learn the steps required to reset the drive
to factory defaults. This lab sets the drive
up for the next two labs. Run Lab A first.

Lab B

Learn how to set up and run the drive in
local (keypad) operation.

Lab C

Learn how to set up and run the drive in
remote (switches and speed pot)
operation.