Running the Demo Unit

4-3

Lab C: Set up the drive for remote operation (based on 2-
wire start stop).

Tools required: None

Step 1. Set parameter A01 [

FREQUENCY

COMMAND

SELECT

]

to equal 01. This changes the source of the drive’s
speed reference to an analog reference.

Step 2. Start the drive by pressing . Notice that the

RUN

LED

and the

LED

above are on.

a. Turn the speed pot located on the drive. Notice

there is no effect. Start/Stop is still from the drive.

b. Turn the remote speed pot. Notice that now you

can vary the speed. Notice also that the

LED

above the drive’s speed pot is not on, indicating
that the drive’s speed pot is not the active speed
reference source.

Step 3. Press to stop the drive

Step 4. Set parameter A02 [

START

COMMAND

SELECT

] to 01.

This changes the source of the Start/Stop control to
the control terminal block.

Step 5. Set parameter C01 [

DIGITAL

INPUT

1] to equal 00

(forward).

Step 6. Set parameter C02 [

DIGITAL

INPUT

2] to equal 01

(reverse).

Step 7. Verify that switches C01 and C02 are both turned to

the left.

Step 8. Turn switch C01 to the right. Notice that the motor

rotates (cw). Then turn the remote speed pot to vary
the speed.

Notice that the

RUN

LED

is on, but the

LED

s above

and the pot are not on.

Step 9. Turn switch C01 back to the left. The motor should

stop.

Step 10. Turn switch C02 to the right. Note that the motor

starts to rotate (in the opposite direction (ccw)). By
turning the remote speed pot, you can vary the
speed.

Step 11. Turn switch C02 back to the left, and the motor will

stop.