3
●
FactoryTalk Historian DataLink Functions
●
●
●
●
●
47
Example:
To see the hourly range of values beginning the same day at midnight until
the present time for the sinusoid tag, the following arguments are set for
the Calculated Data function:
PI Tag
Tagname = sinusoid
Start Time = t
End Time = *
Time Interval = 1h
Calculation Mode = range
Calculation Basis = time-weighted
show start time
show end time
column
The resulting function array appears as: