Install the new power structures in reverse order of removal. Refer to the
publication PFLEX-IN006…, Installation Instructions - PowerFlex 700S
and 700H Drives Frames 9 - 14
, for tightening torques of power and motor
terminations.

Step 4: Connecting the
Power Structures to
Components in the Drive

1. For drives with AC input, connect the precharge cable and remove the

jumper from the fan control connector and connect the fan control cable
from the Rectifying modules to the Power Structure.

2. Use the tables and illustrations below to make all connections between

the ASIC, ASIC Feedback, Common Mode Filter, Power Supply
Voltage Feedback and Fiber Optic Star Interface (700S) or Star Coupler
(700H) circuit boards for your installation.

Refer to

PowerFlex 700S Phase II Drives Connections: on page 16

for

a PowerFlex 700S Phase II circuit board connection diagram.

Refer to

PowerFlex 700H Connections: on page 19

for a PowerFlex

700H circuit board connection diagram.

Important: If the drive has DC input, you must also connect the

precharge circuit. Refer to

Pre-Charge Connections on

Drives with DC Input on page 21

.

=

Connect fan control
cables

Connect Precharge
cables