11

Installation

Cage-clamp terminal block

Connections to the DC3R drive are made to a cage-clamp terminal block
(Figure 4). To insert a wire into the terminal block, press down on the
lever arm using a small screwdriver. Insert stripped wire into the large
opening in front of the terminal block. Release the lever arm to clamp the
wire.

Lever Arm

Figure 4. Cage-Clamp Terminal Block

Field output

The field output is for shunt wound motors only. Do not make any
connections to F1 and F2 when using a permanent magnet motor.

Use 18 AWG wire to connect the field output to a shunt wound motor.
Table 1 lists the field output connections.

Table 1. Field Output Connections

Line Voltage

Approximate

Connect Motor

(VAC)

Field Voltage (VDC) Field To

115

50

F1 and L1

115

100

F1 and F2

230

100

F1 and L1

230

200

F1 and F2