Calibration – Rockwell Automation DC3R Regenerative DC Drive User Guide 1/4 - 2 HP, 115/230 VAC User Manual

Page 36

Advertising
background image

28

Figure 15. Calibration Trimpot Layout

Each drive is factory calibrated to its maximum horsepower rating.
Readjust the calibration trimpot settings to accommodate lower
horsepower motors.

All adjustments increase with CW rotation, and decrease with CCW
rotation. Use a non-metallic screwdriver for calibration. Each trimpot is
identified on the printed circuit board.

ATTENTION:

The following adjustments are made with power on.

Exercise extreme caution as hazardous voltage exists. Failure to
observe this precaution could result in severe bodily injury or loss of
life.

ATTENTION:

The control circuit is at line potential when the drive is

energized. Use a non-metallic screwdriver when making adjustments to
the circuit board potentiometers. Exercise extreme caution as
hazardous voltage exists. Failure to observe these precautions could
result in severe bodily injury or loss of life.

ƽ

Calibration

FORWARD

TORQUE

IR COMP

FORWARD

ACCELERATION

REVERSE

ACCELERATION

REVERSE

TORQUE

MAXIMUM

SPEED

TACH

DEAD
BAND

MINIMUM

SPEED

Advertising